June 3, 2009
Plugging ‘Hot’ Pipes in Extreme
Environments
Some of the world’s most intricate infrastructure is found in power
plants, chemical plants, refineries, and other factories that use and combine
industrial chemicals. The piping for fuel, chemical transport, water supply,
and cooling needs is typically very complex and subject to high temperatures
and pressures. And since plants are harsh environments, it’s a given that
piping needs regular maintenance, repair, and rerouting. But shutting down
entire lines is often considered an impossibility:
practical realities dictate that plants be kept running more or less
continuously, and downtime is simply unacceptable. So, how can repairs to
sections of pipes and lines be made without shutting down
lines and keeping overall systems in operation?
“A great deal of what
we do is in mills and chemical plants, and we have a lot of options in
situations that call for a hot tap,” explains Tom Bowling, P.E., Principal
Engineer for Team Industrial Services, Inc., based in Alvin, Texas, “we can use
a line stop, which to me means inserting a mechanical head into the line and
stopping flow with a rubber cup. We can use a freeze stop in some cases. And
bagging is a technique that solves a lot of customer problems.”
‘Bagging’ is the insertion of a rubber bag into an
active pipe, via a tapping saddle or other mechanism, and inflating the bag
with a gas or liquid so that it unfurls and fills the line. This empties the
downstream side of the plug so it can be worked on safely. Bowling has been
using Inflatable Multi-Flex™ Pipe Plugs and the Hot Tap Pipe Plug Insertion System
from Petersen Products since 1999, when he came across them at a conference on
offshore technology. “The representative gave me a four-inch bag as a sample,
which I still have, and two months later I had a call from Duke Power—they
wanted to plug a 42-inch line located 12 feet under the basement of a nuclear
power plant.” And while he was preparing for that work, another call came in
from a refinery in Southern Louisiana: two banks of exchangers were operating,
but one was contaminated by leaking gas. To fix the leak and keep at least one
exchanger bank working, Team Industrial would have to plug a 16-inch inlet
under 180 psi, with temperatures up to 230ºF. So, two tricky
jobs to take on with new techniques.
A
new technique proves itself
Both projects went well according to Bowling. The Louisiana refinery was
first, and he designed a helpful innovation; “We filled the bag with diesel in
this case,” he says, “that way, if there was a leak, there wouldn’t be
contamination.” Filling the bag with diesel also kept the bag under pressure
without being hooked to a compressor, and in the event the bag held up well.
“We had a spare on hand just in case,” says Bowling, “but the bag was in for
the six months we needed and didn’t fail.” Plugging the nuclear power plant
line also went smoothly, and the plug was kept in place for a week before being
pulled.
Since then, Bowling estimates he’s used Petersen Products bags 40-50
times, almost always custom fabricated. Factors that make bags the right choice
include large pipe size, and he’s used bags to plug lines up to 60-inches in
diameter. Bags are also useful when lines are out of round or uneven internally
due to scaling or buildup, because the rubber adheres to a larger area and
adjusts to irregularities.
Petersen® Line Stop Plugs can be filled with gases or liquids as
needed, and they’ve been used to stop water, chemicals, fuels, and a variety of
hydrocarbon gases, especially low-pressure flare lines. In one case, Team
Industrial inserted a bag into a large water pipe running 40 feet under an
earthen dam, filled the bag with grout, then inserted another bag 150 feet from
the first, filled it with grout, and
filled the area in between with grout—this quickly and effectively sealed off a
660-foot pipe under 40 psi.
“We have been getting a
very good response from our customers,” says Bowling, “because this technique
is just right for some applications and can keep the rest of a system running.
We always work with the customer to figure out the best solution, and sometimes
the bag can’t be beat.”
Angus W. Stocking, L.S.
Team Industrial Services, Inc.:
www.teamindustrialservices.com, 800.662.8326 (281-331-6154)
Petersen Products Co., LLC: www.pipeplug.com,
800.926.1926 (262.692.2416)
|